Find methods for your needs

Refine by Feature
Displaying 1-5 of 7 results for Tag: carbonate removal device
AN72209: Determination of Trace Concentrations of Oxyhalides and Bromide in Municipal and Bottled Waters
Instrument Type: ICTo demonstrate that oxyhalides and bromide can be successfully determined at concentrations required for regulatory standards and guidelines using a Thermo Scientific™ Dionex™ ion chromatography system equipped with a Thermo Scientific™ Dionex™ IonPac™ AS23-4μm column,Thermo Scientific™ Dionex™ CRD 300 Carbonate Removal Device, and a Thermo Scientific™ Dionex™ AERS™ 500 Carbonate Anion Electrolytically Regenerated Suppressor.
Trace Anion Analysis in Ultrapure Water Using an Electrolytic Water Purifier with a Compact Ion Chromatography System: Water Blank
Instrument Type: ICDeterminations of trace anions in ultrapure water are important to the electronics industry. In this record, determinations of ng/L (ppt) anions using large volume concentration are made possible by the Electrolytic Water Purifier(EWP) and AutoPrep modules. Calibration standards are prepared using the AutoPrep large and small loops and EWP-purified water diluent, thereby increasing sensitivity by eliminating sources of contamination. The trace anions are separated on an IonPac AS17-C column designed to improve low level sulfate determinations using a Dionex Integrion compact IC system.
Trace Anion Analysis in Ultrapure Water Using an Electrolytic Water Purifier with a Compact Ion Chromatography System: 50 ppt Standard
Instrument Type: ICDeterminations of trace anions in ultrapure water are important to the electronics industry. In this record, determinations of ng/L (ppt) anions using large volume concentration are made possible by the Electrolytic Water Purifier(EWP) and AutoPrep modules. Calibration standards are prepared using the AutoPrep large and small loops and EWP-purified water diluent, thereby increasing sensitivity by eliminating sources of contamination. The trace anions are separated on an IonPac AS17-C column designed to improve low level sulfate determinations using a Dionex Integrion compact IC system.
TN62: Reducing Carbonate Interference in Anion Determinations with the Carbonate Removal Device (CRD): 5 ppb Perchlorate in 500 mg/L Carbonate, Chloride, and Sulfate Matrix
Instrument Type: ICCarbonate can interfere with accurate quantification of adjoining anions, such as sulfate and perchlorate. Perchlorate is a highly regulated contaminant (EPA Method 314) because of the health risks to pregnant women and prenatal and developing children. Here we show the efficient removal of the carbonate peak from a synthetic high ionic water sample using the Dionex CRD 200 device. In this example, the high ionic water matrix contains: 5 ppb perchlorate in 500 mg/L each of carbonate, sulfate and chloride.
TN62: Reducing Carbonate Interference in Anion Determinations with the Carbonate Removal Device (CRD): Trace Anions
Instrument Type: ICCarbonate can interfere with accurate quantification of adjoining anions, such as sulfate. Here we show the efficient removal of the carbonate peak from a trace analysis water sample using the Dionex CRD 200 device. In this example, a large volume (1000 uL) of water spiked with < 4 ug/L concentration of 17 anions is directly analyzed.