AN72209: Determination of Trace Concentrations of Oxyhalides and Bromide in Municipal and Bottled Waters

Instrument Type: IC

To demonstrate that oxyhalides and bromide can be successfully determined at concentrations required for regulatory standards and guidelines using a Thermo Scientific™ Dionex™ ion chromatography system equipped with a Thermo Scientific™ Dionex™ IonPac™ AS23-4μm column,Thermo Scientific™ Dionex™ CRD 300 Carbonate Removal Device, and a Thermo Scientific™ Dionex™ AERS™ 500 Carbonate Anion Electrolytically Regenerated Suppressor.

Dionex IonPac AS18-4μm Column Performance Test Using its QAR Method

Instrument Type: IC

Before running any samples, Thermo Scientific recommends that you first confirm the performance of the column by reproducing the lot validation report chromatogram shipped with column. Compare your results with the one reported in the quality assurance report. This record provides an eWorkflow for executing the QAR method on an Integrion HPIC system.

AN1155: Determination of Chloride in Infant Formula and Adult Nutritionals

Instrument Type: IC

This application note shows an ion chromatography (IC) determination of chloride in 19 SPIFAN (AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals) matrices. The results show that the method fulfills the SPIFAN standard method performance requirements (SMPRs). Repeatability, recovery, linearity, limit of detection, and limit of quantification were determined according to the chloride AOAC SMPR4 and AOAC Single Lab Validation guidelines. An ICS-6000 can be used for this application.

Dionex IonPac AS23-4µm Column Performance Test Using its QAR Method

Instrument Type: IC

Before running any samples, Thermo Scientific recommends that you first confirm the performance of the column by reproducing the lot validation report chromatogram shipped with column. Compare your results with the one reported in the quality assurance report. This record provides an eWorkflow for executing the QAR method on an Integrion HPIC system.

AU203: Determination of Trace Concentrations of Oxyhalides and Bromide in Municipal and Bottled Waters Using a Compact Ion Chromatography System

Instrument Type: IC

To demonstrate that oxyhalides and bromide can be run successfully using a Thermo Scientific™ Dionex™ Integrion™ HPIC™ system combined with a Thermo Scientific™ Dionex™ IonPac™ AS19-4μm column, featuring smaller resin particles, to achieve faster analysis without compromising data quality compared to using the Dionex IonPac AS19 column as in Application Note 167.