Find methods for your needs

Refine by Feature

No filters available

Displaying 1-5 of 6 results for Tag: RFIC System

Items per page:
Sort by

AN72333: Determination of Adsorbable Organic Halogen in Wastewater using a Combustion Ion Chromatography System

Instrument Type: IC

This application note demonstrates that AOX can be precisely and accurately determined in wastewater using combustion ion chromatography. Analysis was automated using the Mitsubishi AQF–2100H system in combination with the Dionex Integrion HPIC system with a Dionex IonPac AS18-4μm column.

AN72209: Determination of Trace Concentrations of Oxyhalides and Bromide in Municipal and Bottled Waters

Instrument Type: IC

To demonstrate that oxyhalides and bromide can be successfully determined at concentrations required for regulatory standards and guidelines using a Thermo Scientific™ Dionex™ ion chromatography system equipped with a Thermo Scientific™ Dionex™ IonPac™ AS23-4μm column,Thermo Scientific™ Dionex™ CRD 300 Carbonate Removal Device, and a Thermo Scientific™ Dionex™ AERS™ 500 Carbonate Anion Electrolytically Regenerated Suppressor.

AU72197 : Determination of Tobramycin Using HPAE-IPAD on a Compact IC System: 20 µM tobramycin

Instrument Type: IC

Tobramycin is an important aminoglycoside antibiotic used in ophthalmic and intravenous treatments to treat bacterial infections by blocking protein synthesis.[1] Determinations of tobramycin, kanamycin and other aminoglycoside antibiotics have been previously demonstrated by HPAE-IPAD since 2004.[2–6] This document updates Thermo Scientific™ Application Note 61 using a highpressure-capable Dionex Integrion HPIC system equipped with updated EG technology and an electrochemical detector.

TN72206: Configuring the Dionex Modular HPIC System with an Inline Water Purifier and Inline Calibration for Trace Anion Determinations in Ultrapure Water: EWP Water Blank

Instrument Type: IC

In the electronics industry, ionic contamination in the range of parts per trillion (ppt, ng/L) to parts per billion (ppb) concentrations is a major concern, causing corrosion-related failures in production and final product. Ionic contamination is increasingly important as the devices decrease to size. This technical note demonstrates automated calibration and water purification on an ICS-5000+ HPIC dual IC system to minimize the system and environmental contamination which resulted in increased sensitivity to double-digit-ppt concentrations. An ICS-6000 can be used for this application.

TN72206: Configuring the Dionex Modular HPIC System with an Inline Water Purifier and Inline Calibration for Trace Anion Determinations in Ultrapure Water: 50 ppt Standard

Instrument Type: IC

In the electronics industry, ionic contamination, in the range of parts per trillion (ppt, ng/L) to parts per billion (ppb) concentrations, is a major concern causing corrosion-related failures in production and as a product. Ionic contamination is increasingly important as the devices decrease to size. This technical note demonstrates automated calibration and water purification on an ICS-5000+ HPIC dual IC system to minimize the system and environmental contamination which resulted in increased sensitivity to double-digit-ppt concentrations. An ICS-6000 can be used for this application.