Find methods for your needs
Refine by Feature
Displaying 1-5 of 8 results for Tag: IonPac AS17C
TN72206: Configuring the Dionex Modular HPIC System with an Inline Water Purifier and Inline Calibration for Trace Anion Determinations in Ultrapure Water: EWP Water Blank
Instrument Type: ICIn the electronics industry, ionic contamination in the range of parts per trillion (ppt, ng/L) to parts per billion (ppb) concentrations is a major concern, causing corrosion-related failures in production and final product. Ionic contamination is increasingly important as the devices decrease to size. This technical note demonstrates automated calibration and water purification on an ICS-5000+ HPIC dual IC system to minimize the system and environmental contamination which resulted in increased sensitivity to double-digit-ppt concentrations. An ICS-6000 can be used for this application.
TN72206: Configuring the Dionex Modular HPIC System with an Inline Water Purifier and Inline Calibration for Trace Anion Determinations in Ultrapure Water: 50 ppt Standard
Instrument Type: ICIn the electronics industry, ionic contamination, in the range of parts per trillion (ppt, ng/L) to parts per billion (ppb) concentrations, is a major concern causing corrosion-related failures in production and as a product. Ionic contamination is increasingly important as the devices decrease to size. This technical note demonstrates automated calibration and water purification on an ICS-5000+ HPIC dual IC system to minimize the system and environmental contamination which resulted in increased sensitivity to double-digit-ppt concentrations. An ICS-6000 can be used for this application.
离子色谱法同时测定食品中的三种甜味 剂和两种防腐剂
Instrument Type: IC本文研究的三种甜味剂(甜蜜素、安赛蜜、糖精钠)和两种防腐剂(山 梨酸钾、苯甲酸钠),均有国标测定方法,但测定条件不同,不能实现同时 检测。其中,甜蜜素国标测定方法为气相色谱法[4],但其前处理方法比较复 杂,干扰因素多[5]。甜蜜素的分析也可采用高效液相色谱法,紫外检测,但信 号较弱,灵敏度低[6]。通常需采用柱前衍生的方法以增强紫外信号的强度,但 同时增加了样品前处理步骤,且不能同时测定其它甜味剂。 这五种物质分子中都带有易电离的阴离子基团,因此可通过阴离子交换 分离,电导检测器检测[7],因此离子色谱作为合适的测定方法得到很快发展。 本方法采用IonPac AS17-C阴离子交换色谱柱,通过淋洗条件优化,使用两 阶等浓度氢氧化钾淋洗液洗脱,使待测离子和样品基体获得了良好的分离效 果,在多种食品测定中获得了成功的应用。
Trace Anion Analysis in Ultrapure Water Using an Electrolytic Water Purifier with a Compact Ion Chromatography System: Water Blank
Instrument Type: ICDeterminations of trace anions in ultrapure water are important to the electronics industry. In this record, determinations of ng/L (ppt) anions using large volume concentration are made possible by the Electrolytic Water Purifier(EWP) and AutoPrep modules. Calibration standards are prepared using the AutoPrep large and small loops and EWP-purified water diluent, thereby increasing sensitivity by eliminating sources of contamination. The trace anions are separated on an IonPac AS17-C column designed to improve low level sulfate determinations using a Dionex Integrion compact IC system.
Trace Anion Analysis in Ultrapure Water Using an Electrolytic Water Purifier with a Compact Ion Chromatography System: 50 ppt Standard
Instrument Type: ICDeterminations of trace anions in ultrapure water are important to the electronics industry. In this record, determinations of ng/L (ppt) anions using large volume concentration are made possible by the Electrolytic Water Purifier(EWP) and AutoPrep modules. Calibration standards are prepared using the AutoPrep large and small loops and EWP-purified water diluent, thereby increasing sensitivity by eliminating sources of contamination. The trace anions are separated on an IonPac AS17-C column designed to improve low level sulfate determinations using a Dionex Integrion compact IC system.