Find methods for your needs

Refine by Feature

No filters available

Displaying 1-5 of 23 results for Tag: CarboPac PA1

Items per page:
Sort by

AU72197 : Determination of Tobramycin Using HPAE-IPAD on a Compact IC System: 20 µM tobramycin

Instrument Type: IC

Tobramycin is an important aminoglycoside antibiotic used in ophthalmic and intravenous treatments to treat bacterial infections by blocking protein synthesis.[1] Determinations of tobramycin, kanamycin and other aminoglycoside antibiotics have been previously demonstrated by HPAE-IPAD since 2004.[2–6] This document updates Thermo Scientific™ Application Note 61 using a highpressure-capable Dionex Integrion HPIC system equipped with updated EG technology and an electrochemical detector.

CAN119: Determination of Human Milk Oligosaccharides in Human Breast Milk by HPAE-PAD with On-Line Sample Cleanup

Instrument Type: IC

In this study, a method for quantification of six human milk oligosaccharides, namely 2'-fucosyllactose, 3`-fucosyllactose, 3'-sialyllactose, 6'-sialyllactose, lacto-N-tetraose, and lacto-N-neotetraose in breast milk has been developed and validated. The method is based on the HPAE-PAD technique for carbohydrate determinations without sample derivatization. With an on-line sample cleanup using a polymeric reversed-phase column, a “dilute-and-shoot” sample preparation scheme was applied, which significantly reduces sample handling time and therefore increases sample throughput.

TN116: Determination of Bromate by ISO Method 11206

Instrument Type: IC

Bromate is separated using a latexbased anion exchanger and a methanesulfonic acid eluent, followed by a simplified postcolumn reaction to form triiodide. This is subsequently detected by its UV-absorption. Because the reaction takes place at lower pH than other methods, no heating of the reaction coil is needed. These conditions prevent interference from chlorite, which is known to interfere in other bromate determination methods.

TN30: Monosaccharide and Oligosaccharide Analysis of Glycoproteins Electrotransferred onto Polyvinylidene Fluoride (PVDF) Membranes

Instrument Type: IC

This older TN shows how HPAE-PAD carbohydrate analysis can be performed from a PVDF blot. The TN shows monosaccharide, oligosaccharide, and sialic acid analyses. This record reports the monosaccharide analysis method. For updated monosaccharide, sialic acid, and oligosaccharide analysis methods please see records for TN40, AU180, AU181, and AN1050.

AN92: The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Instrument Type: IC

The accurate measurement of the amount of sugar in final molasses is economically important to sugar mills, because the purchase price of the final molasses is directly related to its sugar content. A high-performance anion exchange method with pulsed amperometric detection (HPAE-PAD) was developed to accurately determine the sugar concentrations of cane and beet final molasses samples.