High resolution charge variant analysis of Bevacizumab by ion exchange chromatography using pH gradient buffers

Instrument Type: HPLC (Biocompatible)

Ion exchange separation is applied for charge variant analysis of Bevacizumab using a pH gradient on a Thermo Scientific MAbPac SCX-10 column. The Thermo Scientific Vanquish Flex UHPLC system with UV detection at 280 nm was used with Thermo Scientific CX-1 pH gradient buffers enabled high resolution separation of monoclonal antibody charge variants over a 30 minute gradient.

Concentration determination of a Bevacizumab harvest sample by using an Affinity capture Protein-A column

Instrument Type: HPLC (Biocompatible)

The Thermo Scientific Dionex UltiMate 3000 LC Bio-LC system is applied for the affinity analysis for concentration determination of Bevacizumab Harvest Sample. The analysis was performed on a Thermo Scientific MabPac Protein A column with a UV detection at 280 nm. With a run time of 3.0 minutes, the method allows easy and fast estimation of Protein content in harvest sample of Bevacizumab. Linearity from 0.05-2.0 mg/mL with RSD of 0.5% (n=3)

Separation of oxidized and deamidated impurities of Bevacizumab using Hydrophobic Interaction Chromatography (HIC).

Instrument Type: HPLC (Biocompatible)

The Thermo Scientific Dionex UltiMate 3000 LC Bio-LC system is applied for the Hydrophobic Interaction (HIC) analysis of Bevacizumab. The separation was performed on a Thermo Scientific MabPac HIC-20 column at UV detection of 214 nm. With a total run time of 40 minutes the method allows separation of all oxidized and deamidated impurities of Bevacizumab.

A universal chromatography method for aggregate analysis of monocolonal antibodies

Instrument Type: UHPLC

Analysis of protein aggregation of five important biotherapeutic monoclonal antibodies (mAbs) by size-exclusion chromatography, showing the universal applicability of the Thermo Scientific MAbPac SEC-1 column for aggregate analysis of mAbs. The biopharmaceutical industry continues to develop mAb-based biotherapeutics have several key quality attributes that require quantification. This shows the ability to determine quickly and accurately the percentage of aggregates and fragments for five therapeutics as shown with full details in the AN21601 download.

Influence of Column Temperature on Reversed-Phase Chromatography of an Intact Antibody

Instrument Type: HPLC (Biocompatible)

The Thermo Scientific Vanquish Flex UHPLC System was used in combination with the MAbPac RP column for the reversed-phase analysis of intact bevacizumab. Column thermostatting strongly influences peak shape and recovery. For runs with column temperature set between 60 and 90 °C, peak width at half height is below 3 seconds for a 30 minutes long gradient. The largest peak area is obtained at 70 °C, and decreases steeply at higher and lower column temperatures. Carry-over decreases at higher temperature. At 70 °C the carry-over is estimated at 0.37%.