Optimization and validation of a multi-residue LC-MS/MS method for pesticides in spinach and cabbage by using Thermo Scientific Vanquish UHPLC and TSQ Quantis mass spectrometer. Sample preparation was performed using QuEChERS method that provided high recoveries for an extensive scope of pesticides in several simple steps. Data acquisition and processing were carried out using Thermo Scientific TraceFinder software. The optimized method was validated as per the SANTE guideline and applied to real samples demonstrating that the workflow is fit for purpose.
A robust, sensitive, and reliable multi-residue LC-MS/MS method workflow solution that uses the Thermo Scientific TSQ Altis triple quadrupole mass spectrometer provides analysis and quantitation of more than 160 veterinary drugs with the Thermo Scientific VetDrugs Explorer Collection solution in salmon (fillet), bovine muscle, and milk. The complete instrument and data processing method including SRM settings is included with the VetDrugs Explorer Collection start-to-finish workflow solution. In 17 minutes, the target veterinary drugs were detected and quantified in food matrices.
We present a multi-residue instrumental method that can be applied for high-throughput screening and semi-quantitation of pesticide residues in food matrices at or below the current legislative requirements. A high-resolution, accurate-mass mass spectrometer operated in Full Scan – Variable Data-Independent Analysis (FS-vDIA)* mode provided an option for full spectrum filtering, retrospective analysis, and multi-parameter-based compound identification. The method was validated for 328 target pesticides, with an option for the future extension to a larger number. (*vDIA not available in US.)
As agricultural trade grows and food safety concerns mount, stricter pesticide regulations are being enforced around the world. Increased pesticide testing and reductions in maximum permissible residue levels have driven demand for fast, sensitive and cost-effective analytical methods for high-throughput screening of multi-class pesticides in food. Detection of 510 pesticides at low ppb levels was achieved within 12 minutes using the Thermo Scientific Exactive benchtop LC/MS system powered by Orbitrap technology.
I近年、食の安全へ消費者の関心が高まるなか、食品の残留農薬検査においては、対象となる農薬の数が飛躍的に多くなってきています。また、2006年5月のポジティブリスト制導入により、一度に多成分の農薬を、迅速かつ正確に測定することが求められています。LC/MS/MSシステムはこのような夾雑物を多く含む試料から、選択的に目的化合物を高感度で定量する手法として、近年多くの実績をあげています。ここでは、LC/MS/MSを用いて、農薬35成分を一斉分析した結果をご紹介します。