Trace level quantitation of pesticide residues in leafy vegetables using LC-MS/MS

Instrument Type: LCMSMS

Optimization and validation of a multi-residue LC-MS/MS method for pesticides in spinach and cabbage by using Thermo Scientific Vanquish UHPLC and TSQ Quantis mass spectrometer. Sample preparation was performed using QuEChERS method that provided high recoveries for an extensive scope of pesticides in several simple steps. Data acquisition and processing were carried out using Thermo Scientific TraceFinder software. The optimized method was validated as per the SANTE guideline and applied to real samples demonstrating that the workflow is fit for purpose.

Quantitation of pesticide residues in garlic and cumin using an Orbitrap Exploris 120 high-resolution mass spectrometer

Instrument Type: LCMS

Multi-residue instrumental method that can be applied for high-throughput quantitation of pesticide residues in garlic and cumin at or below the current legislative requirements. The Thermo Scientific Orbitrap Exploris 120 mass spectrometer was operated in two different workflows: using full-scan Data-Independent Acquisition for quantitation and confirmation and using Thermo Scientific AcquireX intelligent data acquisition background exclusion workflow for full spectrum filtering, retrospective analysis, and multi-parameter-based compound identification.

Pesticide residues screening analysis in tea and honey using a Q Exactive Focus High-Resolution Mass Spectrometer

Instrument Type: LCMSMS

We present a multi-residue instrumental method that can be applied for high-throughput screening and semi-quantitation of pesticide residues in food matrices at or below the current legislative requirements. A high-resolution, accurate-mass mass spectrometer operated in Full Scan – Variable Data-Independent Analysis (FS-vDIA)* mode provided an option for full spectrum filtering, retrospective analysis, and multi-parameter-based compound identification. The method was validated for 328 target pesticides, with an option for the future extension to a larger number. (*vDIA not available in US.)

Multi-Residue Pesticide Analysis in Herbal Juices using GC-MS/MS

Instrument Type: GCMSMS

The Thermo Scientific™ TSQ™ 8000 Evo triple quadrupole GC-MS is an excellent tool for the control of MRL levels in food commodities. The enhanced velocity optics (EVO) driving EvoCell collision cell technology provide high SRM transition speeds, precision, and sensitivity for even complex methods involving several pesticides in a short run time. This application is focused on the analysis of 247 compounds in two different herbal juices, Aloe vera and Amla (Indian gooseberry), demonstrating the potential of the method to detect trace level compounds at concentrations as low as 1-2 ng/g.

Non-targeted Screening and Accurate Mass Confirmation of 510 Pesticides on the High Resolution Exactive Benchtop LC/MS Orbitrap Mass Spectrometer

Instrument Type: LCMS

As agricultural trade grows and food safety concerns mount, stricter pesticide regulations are being enforced around the world. Increased pesticide testing and reductions in maximum permissible residue levels have driven demand for fast, sensitive and cost-effective analytical methods for high-throughput screening of multi-class pesticides in food. Detection of 510 pesticides at low ppb levels was achieved within 12 minutes using the Thermo Scientific Exactive benchtop LC/MS system powered by Orbitrap technology.