Displaying 1-5 of 8 results for Tag: Syncronis C8

Items per page:
Sort by

Related substances analysis of sulfamethoxazole using a C8 HPLC column as per EP 8.0 monograph method

Instrument Type: HPLC

The Thermo Scientific Dionex UltiMate 3000 LC system is applied for the related substances analysis of Sulfamethoxazole. The analysis was performed on a Thermo Scientific Syncronis C8 HPLC column using the method described in the EP-8.0 monograph. The results obtained for peak resolution and relative retention times exceeded the criteria stated in the EP. Resolution between sulfamethoxazole and Impurity-A was 5.7 (EP criteria of not less than 3.5).

Separation of related impurities of Furosemide injection as per BP Monograph.

Instrument Type: HPLC

The Thermo Scientific Dionex UltiMate 3000 LC system is applied for the separation of related impurities of Furosemide Injection as per BP Monograph 2007. The separation was performed on a Thermo Scientific Syncronis C8 HPLC column with UV detection at 238 nm. With a total run time of 36 minutes the method allows separation of all related impurities of Furosemide. The obtained Relative retention time of Impurity C, B, A, E and D with respect to Furosemide peak are as 0.39, 0.43, 0.76, 1.28 and 1.5 minutes respectively

USP 38 monography - assay of lovastatin related compound A using a C8 HPLC column

Instrument Type: HPLC

The Thermo Scientific Dionex UltiMate 3000 LC system is applied for the assay analysis of lovastatin related compound-A. The analysis was performed on a Thermo Scientific Syncronis C8 HPLC column using the method described in the USP 38 monograph. Resolution between lovastatin and lovastatin related compound A was 10.9 (exceeded USP criteria of NLT 6.0). Relative retention time of lovastatin related compound A with respect to lovastatin was 1.39 (met USP criteria of about 1.3). The % RSD for replicate injection of standard solution was 0.9% (exceed USP criteria not more than 5.0%).

Analysis of fenoprofen using the USP method with a Thermo Scientific Syncronis C8 HPLC column

Instrument Type: HPLC

The USP monograph for Fenoprofen, requires an L7 column with 5µm packing, therefore a Thermo Scientific Syncronis C8, 5µm column would be suitable and is demonstrated in this work.

Fast analysis of norethindrone and mestranol with progesterone as internal standard using a Thermo Scientific Syncronis C8 HPLC column

Instrument Type: HPLC

The Thermo Scientific UltiMate 3000 system is applied for the determination of norethindrone and mestranol with progesterone as internal standard. The separation is performed on a Thermo Scientific Syncronis C8 HPLC column, with UV detection at 200 nm.