High resolution charge variant analysis of Cetuximab by ion exchange chromatography using pH gradient buffers

Instrument Type: HPLC (Biocompatible)

The Thermo Scientific MAbPac SCX-10 column is applied to the charge variant analysis of Cetuximab. Ion exchange separation was performed using a pH gradient on a Thermo Scientific Vanquish Flex UHPLC system with UV detection at 280 nm. Use of Thermo Scientific CX-1 pH gradient buffers enabled high resolution separation of monoclonal antibody charge variants over a 30 minute gradient.

High resolution charge variant analysis of Infliximab by ion exchange chromatography using pH gradient buffers

Instrument Type: HPLC (Biocompatible)

The Thermo Scientific MAbPac SCX-10 column is applied for charge variant analysis of Infliximab. Ion exchange separation was performed on a Vanquish Flex UHPLC system using a pH gradient and UV detection at 280 nm. Use of Thermo Scientific CX-1 pH gradient buffers enabled high resolution separation of monoclonal antibody charge variants over a 30 minute gradient.

High resolution charge variant analysis of Bevacizumab by ion exchange chromatography using pH gradient buffers

Instrument Type: HPLC (Biocompatible)

Ion exchange separation is applied for charge variant analysis of Bevacizumab using a pH gradient on a Thermo Scientific MAbPac SCX-10 column. The Thermo Scientific Vanquish Flex UHPLC system with UV detection at 280 nm was used with Thermo Scientific CX-1 pH gradient buffers enabled high resolution separation of monoclonal antibody charge variants over a 30 minute gradient.

Separation of Acidic and Basic charge variants of Denosumab by Ion Exchange chromatography using pH Gradient Buffers

Instrument Type: HPLC (Biocompatible)

The Thermo Scientific Dionex UltiMate 3000 LC Bio-LC system is applied for the Ion Exchange analysis of Denosumab. The separation was performed on a Thermo Scientific MAbPac SCX-10 and pH gradient buffers with a UV detection at 280 nm. With a run time of 50 minutes the method allows easy separation of charge variants of Denosumab.

Separation of Acidic and Basic charge variants of Denosumab by Ion Exchange chromatography using Salt Gradient Method

Instrument Type: HPLC (Biocompatible)

The Thermo Scientific Dionex UltiMate 3000 LC Bio-LC system is applied for the Ion Exchange analysis of Denosumab. The separation was performed on a Thermo Scientific MabPac SCX-10 column with a UV detection at 220 nm. With a run time of 65 minutes the method allows easy separation of charge variants of Denosumab.