Find methods for your needs

Refine by Feature

No filters available

Displaying 1-5 of 7 results for Tag: CarboPac PA200

Items per page:
Sort by

AU206: Improved Separation of Aminobenzamide (2-AB)-Labeled N-glycans from Human α1 Acid-Glycoprotein for Analysis by HPAE-FLD

Instrument Type: IC

This application update demonstrates improved chromatographic separation achieved using a Thermo Scientific™ Dionex™ CarboPac™ PA200 column for the HPAE-FLD method described in proposed United States Pharmacopeia (USP) General Chapter <212> to separate 2-AB-labeled N-linked oligosaccharides from human α1 acid-glycoprotein. An ICS-6000 can be used for this application.

AN1149: Profiling Fructosyloligosaccharides (FOS)-containing samples by HPAE-PAD

Instrument Type: IC

In this work, the oligo- and polysaccharide distribution of three different inulin samples has been characterized by HPAE-PAD. In addition, HPAE-PAD profiling was demonstrated as a method to determine FOS content in prebiotic samples and variation in prebiotics on addition of probiotics. We used Inulin-FOS and chicory root inulin as prebiotic samples. For probiotics, we used Yakult drink, a well known probiotic dairy product. In this method, separation of individual oligosaccharides in FOS was achieved on a Dionex CarboPac PA200 column. An ICS-6000 can be used for this application.

AN1091: Determination of Uronic Acids and Wood Sugars in Wood-Based Hydrolysates: Uronic Acid Method

Instrument Type: IC

Wood, grass, and other lignocellulosic biomass are emerging as the preferred sources for biofuel and biochemical production. Compositional analysis of plant derived material is crucial for maximizing the yield of biofuel production. This record shows an HPAE-PAD Method that uses the Dionex CarboPac PA200 column to determine uronic acids in wood hydrolysates.

AU176: Preparation of Peptide N-Glycosidase F Digests for HPAE-PAD Analysis

Instrument Type: IC

The work shown here describes glycoprotein deglycosylation with PNGase F, followed by an efficient sample pretreatment using desalting and detergent removal spin columns to remove high concentrations of salt and detergents from small-scale PNGase F digestions. The HPAE-PAD technique was used to separate and detect the oligosaccharides. Oligosaccharides were separated using the Dionex CarboPac PA200 column. The PA200 is a nonporous, high-efficiency, pellicular anion-exchange column that provides high-resolution separations required for oligosaccharide mapping and analysis.

AN1050: Evaluating Protein Glycosylation in Limited-Quantity Samples by HPAE-PAD - Oligosaccharide Method

Instrument Type: IC

By using a combination of acid hydrolysis and enzymatic digestion steps prior to HPAE-PAD analysis, information about a protein's glycosylation, as well as linkages within the glycans, is determined. These methods provide a cost-effective option for investigating glycans without the derivatization required by many other methods. This record details a method for oligosaccharide analysis.