Find methods for your needs

Refine by Feature

More...
More...
More...
Name
CAS Number
More...
Class
More...
Manufacturer
More...
Model
More...
Stationary Phase
More...
Dimensions
Length
Diameter/Tubing Size ID
Tubing Size OD
Particle Size/Film Thickness

Displaying 1-5 of 9 results

Items per page:
Sort by

Trace level quantitation of pesticide residues in leafy vegetables using LC-MS/MS

Instrument Type: LCMSMS

Optimization and validation of a multi-residue LC-MS/MS method for pesticides in spinach and cabbage by using Thermo Scientific Vanquish UHPLC and TSQ Quantis mass spectrometer. Sample preparation was performed using QuEChERS method that provided high recoveries for an extensive scope of pesticides in several simple steps. Data acquisition and processing were carried out using Thermo Scientific TraceFinder software. The optimized method was validated as per the SANTE guideline and applied to real samples demonstrating that the workflow is fit for purpose.

Pesticide residues screening analysis in tea and honey using a Q Exactive Focus High-Resolution Mass Spectrometer

Instrument Type: LCMSMS

We present a multi-residue instrumental method that can be applied for high-throughput screening and semi-quantitation of pesticide residues in food matrices at or below the current legislative requirements. A high-resolution, accurate-mass mass spectrometer operated in Full Scan – Variable Data-Independent Analysis (FS-vDIA)* mode provided an option for full spectrum filtering, retrospective analysis, and multi-parameter-based compound identification. The method was validated for 328 target pesticides, with an option for the future extension to a larger number. (*vDIA not available in US.)

Non-targeted Screening and Accurate Mass Confirmation of 510 Pesticides on the High Resolution Exactive Benchtop LC/MS Orbitrap Mass Spectrometer

Instrument Type: LCMS

As agricultural trade grows and food safety concerns mount, stricter pesticide regulations are being enforced around the world. Increased pesticide testing and reductions in maximum permissible residue levels have driven demand for fast, sensitive and cost-effective analytical methods for high-throughput screening of multi-class pesticides in food. Detection of 510 pesticides at low ppb levels was achieved within 12 minutes using the Thermo Scientific Exactive benchtop LC/MS system powered by Orbitrap technology.

Routine, Targeted and Non-Targeted Analysis of Environmental Contaminants of Emerging Concern - Development and Validation of a UHPLC Orbitrap MS Method

Instrument Type: LCMS

Contaminants of emerging concern (CEC) in the environment are generally described as compounds that are unknown or unrecognized, undetected or not routinely monitored, and represent a diverse group of chemicals that may pose a risk to human health and the environment. Due to limited analytical capability and available resources , monitoring of CECs has been focused on selected analytes rather than a holistic approach. We describe a new analytical method that can be used in the quantitative analysis of 61 targeted and 312 non-targeted CECs.

Screening for 250 Pesticides in Orange Oil and Ginseng Extract by LC-MS/MS Using TraceFinder Software

Instrument Type: LCMSMS

We developed a quick and efficient LC-MS/MS method for screening pesticides in orange oil and ginseng extract using TraceFinder software.