Confident analysis of ultra-trace pesticides residues in baby food using triple quadrupole GC-MS

Instrument Type: GCMSMS

The aim of this application note is to demonstrate the performance of the Thermo Scientific™ TSQ™ 9610 triple quadrupole mass spectrometer coupled to the Thermo Scientific™ TRACE™ 1610 GC equipped with programmable temperature vaporizing injector (PTV) for the determination of trace level pesticide residues in baby food.

Simultaneous screening and quantification of pesticide residues in potato using GC-Orbitrap MS

Instrument Type: GCMS

This work aimed to develop and validate an analytical method for simultaneous screening and quantification of pesticide residues in potato by using the QuEChERS extraction method in combination with the Thermo Scientific™ Exactive™ GC Orbitrap™ GC-MS system operated in full scan mode. The data acquisition and processing were carried out by using Thermo Scientific™ TraceFinder™ software. The optimized method was validated as per the SANTE/12682/2019 guidelines.

Ultra low level quantification of pesticides in baby foods using an advanced triple quadrupole GC-MS/MS system

Instrument Type: GCMSMS

In this study, the quantitative performance of the Thermo Scientific™ TSQ™ 9000 triple quadrupole GC-MS/MS system was assessed for the analysis of more than 200 pesticides in baby food at ultra low concentrations (as low as 0.025 μg/kg).

Pesticide residues screening analysis in tea and honey using a Q Exactive Focus High-Resolution Mass Spectrometer

Instrument Type: LCMSMS

We present a multi-residue instrumental method that can be applied for high-throughput screening and semi-quantitation of pesticide residues in food matrices at or below the current legislative requirements. A high-resolution, accurate-mass mass spectrometer operated in Full Scan – Variable Data-Independent Analysis (FS-vDIA)* mode provided an option for full spectrum filtering, retrospective analysis, and multi-parameter-based compound identification. The method was validated for 328 target pesticides, with an option for the future extension to a larger number. (*vDIA not available in US.)

Forensic Screening for Drugs in Urine Using High-Resolution MS/MS Spectra and Simplified High-Performance Screening Software

Instrument Type: LCMSMS

Forensic toxicologists need an economical solution to screen for a virtually unlimited number of compounds in urine. Here we present a method for screening using a dilute-and-shoot approach with the Q Exactive Focus mass spectrometer and Thermo Scientific ToxFinder software. For forensic use only.