Find methods for your needs

Refine by Feature

More...
More...
More...
Name
CAS Number
More...
Class
More...
Manufacturer
More...
Model
More...
Stationary Phase
More...
Dimensions
Length
Diameter/Tubing Size ID
Tubing Size OD
Particle Size/Film Thickness

Displaying 1-5 of 11 results

Items per page:
Sort by

Analysis of underivatized amino acids in wines by solid phase extraction and HILIC-MS

Instrument Type: LCMS

Solid phase extraction cleans up wines reproducibly and reliably, facilitating analysis of underivatized amino acids in wines. Mass detection enables the quantification of co-eluting amino acids, in comparison with method involving derivatization and UV or FL detection.

Underivatized amino acid analysis in wine by HILIC separation and mass detection

Instrument Type: LCMS

Development of a sensitive and reproducible method for analysis of 22 underivatized amino acids and application of the method to quantify 17 amino acids in wine. Accurate quantification of proline, using an isotopically labeled internal standard.

Simultaneous Analysis of Amino Acids, Acylcarnitines, and Succinylacetone in Dried Blood Spots for Research Using Nonderivatized and Derivatized Methods

Instrument Type: LCMSMS

We developed a flow injection analysis-tandem mass spectrometry (FIA-MS/MS) research methods for simultaneous detection and quantification of 12 amino acids, 18 acylcarnitines, and succinylacetone in dried blood spots and compare derivatization and nonderivatization sample preparation methods.

AU152: An Improved Gradient Method for the AAA-Direct™ Separation of Amino Acids and Carbohydrates in Complex Sample Matrices

Instrument Type: IC

In this Application Update, we combine into a single method individual improvements made to the standard AAA-Direct gradient program. These individual improvements are now in the AAA-Direct manual. This update shows that such combined changes to the AAA-Direct method improve the performance of our previously published method. This new method successfully determines amino acids in yeast extract-peptone-dextrose yeast culture medium (YPD Broth), and Dulbecco’s modified Eagle’s (with F-12), M199, L-15 (Leibovitz), and McCoy’s 5A media for mammalian cell culture.

TN55: Screening of Sample Matrices and Individual Matrix Ingredients for Suitability in AAA-Direct

Instrument Type: IC

In this technical note, we describe a procedure to screen sample matrices for their effect on peak area, peak height, and retention time. We demonstrate this procedure by testing ethanol for possible interferences in AAA-Direct. However, the method described here can also be used to evaluate any matrix component analyzed by chromatography with electrochemical detection. In this technical note, we use the term test sample (TS) to describe the specific test compound evaluated for possible interferences.