AN1152: Determination of Carbohydrates in Kombucha Using HPAE-PAD
Instrument Type: ICThe method uses the Thermo Scientific™ Dionex™ CarboPac™ PA20 column with electrolytically generated hydroxide eluent and a 15 mil gasket for the gold working electrode to separate and detect glucose, fructose and sucrose in kombucha.
Determination of High Sugar Concentrations in an Irish Whiskey Sample Using a Compact Ion Chromatography System
Instrument Type: ICThis record demonstrates the determinations of glucose, fructose, and sucrose in a 5-fold diluted Irish whiskey sample by HPAE-PAD. Typically samples with g/L concentrations require >1000-fold dilutions to remain in the linear range of the very sensitive HPAE-PAD technique. However, this method, demonstrated on the Integrion RFIC system, uses a 0.4 µL internal injection loop with the High Concentration Carbohydrate Analysis Kit to extend the linearity from low mg/L to g/L concentrations. A wood hydrolysate application using this technique is attached for reference.
Determination of High Sugar Concentrations in a Flavored Rum Liquor Sample Using a Compact Ion Chromatography System
Instrument Type: ICThis record demonstrates the determinations of glucose, fructose, and sucrose in a 100-fold diluted flavored rum alcohol sample by HPAE-PAD. Typically samples with g/L concentrations require > 10,000-fold dilutions to remain in the linear range of the very sensitivie HPAE-PAD technique. However, this method, demonstrated on the Integrion RFIC system, uses a 0.4 µL internal injection loop with the High Concentration Carbohydrate Analysis Kit to extend the linearity from low mg/L to g/L concentrations. A wood hydrolysate application using this technique is attached for reference.
Determination of High Sugar Concentrations in a Rice Wine Sample Using a Compact Ion Chromatography System
Instrument Type: ICThis record demonstrates the determinations of glucose and fructose in a 100-fold diluted rice wine sample by HPAE-PAD. Typically samples with g/L concentrations require > 10,000-fold dilutions to remain in the linear range of the very sensitive HPAE-PAD technique. However, this method, demonstrated on the Integrion RFIC system, uses a 0.4 µL internal injection loop with the High Concentration Carbohydrate Analysis Kit to extend the linearity from low mg/L to g/L concentrations. A wood hydrolysate application using this technique is attached for reference.
Determination of High Sugar Concentrations in a Malbec Wine Sample Using a Compact Ion Chromatography System
Instrument Type: ICThis record demonstrates the determinations of glucose in a 100-fold diluted Malbec wine sample by HPAE-PAD. Typically samples with g/L concentrations require > 10,000-fold dilutions to remain in the linear range of the very sensitive HPAE-PAD technique. However, this method, demonstrated on the Integrion RFIC system, uses a 0.4 µL internal injection loop with the High Concentration Carbohydrate Analysis Kit to extend the linearity from low mg/L to g/L concentrations. A wood hydrolysate application using this technique is attached for reference.