AN363: Using Accelerated Solvent Extraction in Alternative Fuel Research
Instrument Type: Automated Sample PrepThe Accelerated Solvent Extraction (ASE) provides a fast and efficient way to extract various biomass samples for sugar analysis to determine sample viability for alcohol production. This application note describes methods for the extraction of sugars from biomass samples using acidified solvents (in-cell hydrolysis) and extracting pre-hydrolyzed samples.
AN1161: Improved Method for Determination of Biofuel Sugars by HPAE-PAD
Instrument Type: ICThe current work updates the system used for the carbohydrate analysis in AN1089. The new system combines flexibility and ease-of-use with high sensitivity and selectivity, bringing a higher level of convenience and cost effectiveness to simple sugar analysis. The method proposed here separates eight common carbohydrate sugars in less than eight minutes. The shorter run time results in better process economics. Using this method, carbohydrates present in 10 individual biofuel samples were quantified.
TN186: The Effect of Working Electrode Gasket Thickness on the Sensitivity and Linearity of Carbohydrate Response by PAD with the Dionex™ CarboPac™ SA10 Column
Instrument Type: ICHPAE-PAD is widely used for determination of carbohydrates by measuring the electrical current generated by their oxidation at the surface of a gold electrode. Each amperometric detection cell includes an amperometric working electrode exposed to a sample flow-through channel, typically enclosed by a plastic gasket held in place by compression. Here, the sensitivity and linearity of six carbohydrates have been evaluated using 2, 15, and 62 mil gaskets under typical chromatographic conditions used for Thermo Scientific™ Dionex™ CarboPac™ SA10 column with and without postcolum addition.
TN186: The Effect of Working Electrode Gasket Thickness on the Sensitivity and Linearity of Carbohydrate Response by PAD with the Dionex™ CarboPac™ PA20 Column
Instrument Type: ICHPAE-PAD is widely used for determination of carbohydrates by measuring the electrical current generated by their oxidation at the surface of a gold electrode. Each amperometric detection cell includes an amperometric working electrode exposed to a sample flow-through channel, typically enclosed by a plastic gasket held in place by compression. Here, the sensitivity and linearity of six carbohydrates have been evaluated using 2, 15, and 62 mil gaskets under typical chromatographic condition used for Thermo Scientific™ Dionex™ CarboPac™ PA20 column.
Dionex CarboPac PA210-Fast-4µm Column Performance Test Using its QAR Method
Instrument Type: ICBefore running any samples, Thermo Scientific recommends that you first confirm the performance of the column by reproducing the lot validation report chromatogram shipped with column. Compare your results with the one reported in the quality assurance report. At least three injections should be made. This record provides an eWorkflow for executing the QAR method on an ICS-5000+ system. An ICS-6000 can be used for this application.