Find methods for your needs

Refine by Feature

No filters available

Displaying 1-5 of 8 results for Tag: Methylamine

Items per page:
Sort by

AU155: Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Instrument Type: IC

Hydrogen peroxide is an essential chemical in the fabrication of integrated circuit and microcircuit devices. Maximum allowable contaminate levels for semiconductor grade hydrogen peroxide can be as low as <100 ppt (ng/L) per individual inorganic cation. This application uses an IonPac CS17 column to determine trace cations and amines in hydrogen peroxide with a large-loop injection. The CS17 column separates amines without the organic solvent eluent modifier needed for separating amines when using older cation-exchange ion-chromatography (IC) columns.

AN269: Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

Instrument Type: ICMS

The work shown here demonstrates the use of IC-MS for the determination of six commonly found cations and selected amines on an IonPac CS12A-5µm column. Confirmatory information was obtained using full-scan MS spectra showing positively charged cation species and characteristic adduct patterns. Quantification was achieved using selected ion monitoring (SIM) acquisitions for each target analyte.

AN94: Determination of Trace Cations in Concentrated Acids (Sulfuric Acid) Using AutoNeutralization Pretreatment and Ion Chromatography

Instrument Type: IC

The determination of trace cationic contamination in processing acids (phosphoric, sulfuric, hydrofluoric) is important to the electronics industries to minimize corrosion. Here trace cationic contamination is determined in a 24% sulfuric acid sample. The acid sample is automatically neutralized through an electrolytic device, and then retained and concentrated onto a concentrator column. After eluting from the concentrator column, the µg/L cations are determined on an IonPac CS16 column using electrolytically generated MSA eluent and suppressed conductivity detection.

AN94: Determination of Trace Cations in Concentrated Acids (Phosphoric Acid) Using AutoNeutralization Pretreatment and Ion Chromatography

Instrument Type: IC

The determination of trace cationic contamination in processing acids (phosphoric, sulfuric, hydrofluoric) is important to the electronics industries to minimize corrosion. Here trace cationic contamination is determined in a 25% phosphoric acid sample. The acid sample is automatically neutralized through an electrolytic device, and then retained and concentrated onto a concentrator column. After eluting from the concentrator column, the µg/L cations are determined on an IonPac CS16 column using electrolytically generated MSA eluent and suppressed conductivity detection.

AN94: Determination of Trace Cations in Concentrated Acids (Hydrofluoric Acid) Using AutoNeutralization Pretreatment and Ion Chromatography

Instrument Type: IC

The determination of trace cationic contamination in processing acids (phosphoric, sulfuric, hydrofluoric) is important to the electronics industries to minimize corrosion. Here trace cationic contamination is determined in a 10% hydrofluoric acid sample. The acid sample is automatically neutralized through an electrolytic device, and then retained and concentrated onto a concentrator column. After eluting from the concentrator column, the µg/L cations are determined on an IonPac CS16 column using electrolytically generated MSA eluent and suppressed conductivity detection.