Displaying 1-5 of 79 results for Tag: HPAE-PAD

Items per page:
Sort by

AN1089: Determination of Carbohydrates in Acid Hydrolysates of Wood - Method 2

Instrument Type: IC

This work develops methods for the determination of carbohydrates in wood acid hydrolysates using a CarboPac SA10-4μm column, along with a 0.4 µL injection and thicker working electrode gasket. This column contains smaller resin particles, enabling high-resolution, high-efficiency separation, particularly for the rhamnose-galactose that has been challenging to resolve with previous methods. The described method is fast, provides good sensitivity and consistent response, and can be routinely used to determine sugars in wood samples. An ICS-6000 can be used for this application.

AN1089: Determination of Carbohydrates in Acid Hydrolysates of Wood - Method 1

Instrument Type: IC

This work develops methods for the determination of carbohydrates in wood acid hydrolysates using the CarboPac SA10-4μm column, along with a 0.4 µL injection and thicker working electrode gasket. This column contains smaller resin particles, enabling high-resolution, high-efficiency separation, particularly for rhamnose-galactose that has been challenging to resolve with previous methods. The described method is fast, provides good sensitivity and consistent response. An ICS-6000 can be used for this application.

TN72225: Glycoprotein Monosaccharide Analysis using HPAE-PAD with Manually Prepared Eluent

Instrument Type: IC

This work describes an HPAE-PAD method for monosaccharide composition analysis using manually prepared eluent. Monosaccharide analysis using electrolytically generated eluent has been described before. Here, three commercially available proteins, IgG, fetuin, and alpha-1-acid glycoprotein, were individually subjected to two hydrolysis conditions using 1)HCl, for the amino sugars galactosamine and glucosamine, and 2)TFA, for the neutral sugars mannose, glucose, and galactose. Results for method linearity, robustness, and accuracy are presented here. An ICS-6000 can be used for this application.

AN72210: Fast Determination of Biofuel Sugars by HPAE-PAD

Instrument Type: IC

This work updates the column used in AN1161 with a shorter 4 × 150 mm format column. The combination of the smaller resin particle size of the Dionex CarboPac SA10-4μm column and the shorter column used here results in separation of eight common sugars in less than six minutes. This is significant time savings as compared to the eight-minute runtime achieved in AN1089. The shorter run time allows for faster sample turnaround times and reduced eluent consumption, thereby improving the overall process economics. Results for method linearity, accuracy, and robustness are presented here.

TN186: The Effect of Working Electrode Gasket Thickness on the Sensitivity and Linearity of Carbohydrate Response by PAD with the Dionex™ CarboPac™ SA10 Column

Instrument Type: IC

HPAE-PAD is widely used for determination of carbohydrates by measuring the electrical current generated by their oxidation at the surface of a gold electrode. Each amperometric detection cell includes an amperometric working electrode exposed to a sample flow-through channel, typically enclosed by a plastic gasket held in place by compression. Here, the sensitivity and linearity of six carbohydrates have been evaluated using 2, 15, and 62 mil gaskets under typical chromatographic conditions used for Thermo Scientific™ Dionex™ CarboPac™ SA10 column with and without postcolum addition.